1. Features |
|
Special CMOS integrated circuit,super small bulk,high relia
High repeat accuracy:±20% (including the initiate) shorter reset time :0.1 second (Max).
Led indicating operating .
socket for electromagent relay can be used.
pule output (HT6U). |
| |
|
2. Application
|
| |
Output Controlload: HT6-29(-0):5A 250VAC;5A30VDC resistant loadHT6-4(-0):3A 250VAC; 3A 30VDC resistant loadTH6U:3A 30VDC resistant loadRated voltage:
(see selecting code)
single phase entire wave rectifier power can be used ofr DC voltage on 85% to 110% of rated voltage (90% to 110% for 12VDC). |
| |
| |
|
3. Power Dissipation: |
| |
|
1W for DC
2.2W for AC |
| |
| |
|
4. Socket
|
| |
DIN rail mounting:mounting:PYF08A/HT6-2,Yf14A/HT6-4 PCB
Jointing mounting:PY08/HT6-2,PY14/HT6-4
PCB mounting:PY08-0/HT6-2,PY14/HT6-4 |
| |
| |
5. Selection Model |
| |
|
| |
6. General parameters |
| |
Repeat error |
±2% (Max) |
Schedule error |
±10% (with in 0.5s:±10Ms) |
Reset time |
0.1s (Max) |
iming error for operating voltage |
±2% |
Timing error for ambienttemperature |
±5% |
Insulation resistance |
100Mohms @500VDC |
Dielectric strength |
1500VAC 50/60 Hz lmin,(input to contact)1000VAC 50/60Hz 1 min.(between the contacts) |
Ambient temperature storage |
-10℃ to 50℃ operating:-10℃ to 40℃ |
Relatve humidity |
35% to 85% |
Vibration |
0 to 55Hz, 1.0mm double amplitude |
Mechanical life |
atleast 10000000times (1800times /hour no load added on the contact) |
Electric life |
100000times (rated load) |
weight |
50g |
|
| |
| |
7. Diminsions |
| |
|
| |
| |
8. Connection/Timing Charts |
| |
|
| |
|
| |
|
| |
| |
|
|